Brand Name: | NBSANMINSE |
Model Number: | QD - Z - 40S / 50S |
Certification: | ISO9001 |
Place of Origin: | CHINA |
MOQ: | 20 |
Price: | Negotiation |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | Negotiation |
Delivery Time: | Negotiation |
Packaging Details: | Plastic Bags , Boxes , Carton , Pallet Or As Customer Advice |
Pressure: | 0 . 3 - 0 . 6MPa |
Temperature: | - 25 ~ 60 ℃ |
Relative Humidity: | ≤ 85 % |
Medium: | Clean Air |
Voltage: | DC24V / AC110V / Etc |
Diaphragm: | Double Diaphragm |
Diameter: | G1 - 1 / 2 " , G2 " |
Body: | ADC 12 Die Cast |
Company Info. |
Ningbo Sanmin Import And Export Co.,Ltd. |
Verified Supplier |
View Contact Details |
Product List |
QD - Z - 40S / 50S Series Electromagnetic Pulse Valve GOYEN Replace
G1 - 1 / 2 " , G2 " Dust proof valve Dust Control Valve
Usage
Electromagnetic valve ( Also called diaphragm valve ) is the”
switch “for compressed air in the dust clean blowing system of the
pulse bag filter . Controlled by the output signals of the pulse
jet control device , it makes dust clean to the filter bags cell by
cell to keep the resistance of thebaghouse within the set range and
thus guarantee the processing functions and the dust collecting
efficiency of the baghouse .
Z type electromagnetic pulse valves is a right angle valve , with
the 90 degree , angle between the inlet and outlet , which is
suitable for the installation connection between the gas dome and
the baghouse blow tube provide good air flow and dust clean pulses
satisfying the requirements .
During installation and commissioning
Failure phenomena
1 . The valves cannot all be opened, but the leading part does act.
2 . Some valves do not work, but the others are normal.
3 . The valves cannot all be closed. There is leakage. There is no
way to establish a gas dome.
4 . Some valves cannot be closed. There is leakage.
5 . A valve closing is slowly.
Possible Reason
1 . Check the gas dome pressure to see if it is too low.
2 . Check the valve coil connection and coil
3 ( 1 ) . Y-valve. Some valves for the same gas dome are leaking,
thus causing leakage for all the valves.
3 ( 2 ) . Z-valve. The valve inlet and blowing muzzle are installed
backwards.
4 . There is some dirt or debris on the membrane, ii is blocking
the moving iron core.
5 . The membrane orifice is blocked.
Troubleshooting
1 . Check the leakage
2 . Replace the accessories
3 ( 1 ) . Check the leakage
3 ( 2 ) . Re-install
4 . Clean the membrane and check that the membrane is complete.
Check the moving iron core and air lock.
5 . Dredge the membrane orifice
During use period
Failure phenomena
1 . Some valves are leaking. The membrane cannot close tightly and
the valve is always open a
little.
2 . Coil is hot and burned out.
3 . Voltage exists but the valve does not operate.
4 . Ambient temperature is below -20℃. The valve is leaking and
cannot open.
Possible Reason
1 . There is some dirt or debris on the membrane, the leading part
is damaged. Moving iron core is blocked.
2 . It has been turned on for too long.
3 . Membrane is damaged and the orifice is blocked.
4 . Ambient temperature is too low and here is frost in the valve.
Troubleshooting
1 . Clean the membrane and check that the membrane piece is
complete. Check the moving iron core and the air lock. Replace the
accessories if necessary.
2 . Check the working condition of the control system.
3 . Replace the accessories in time.
4 . Pay attention to insulation and maintaining proper
temperatures.
![]() |