Sign In | Join Free | My chinacsw.com
chinacsw.com
Products
Search by Category
Wholesale Marketplace
Home >

LXC31X0 Series Diesel Generator Control Panel 32 Bit Arm Processor

Categories Generator Accessories
Place of Origin: China
Brand Name: GSKA
Model Number: LXC31X0
MOQ: 1-5 pieces
Price: Negotiable
Packaging Details: Standard plywood and wood package.the actual package size against goods size and handle requires. Si
Delivery Time: one weeks on receipt of official sales contract
Payment Terms: L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability: 500 pieces per Month
Port:: HongKong or ShenZhen,ShangHai,Dalian as required
CertifiCAT-partsion: CE/RoHs/ISO9001
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    LXC31X0 Series Diesel Generator Control Panel 32 Bit Arm Processor


    LXC31X0 Series Diesel Generator Control Panel 32 Bit Arm Processor


    1. Summary
    LXC31X0 Series automation controller uses 32-bit ARM processor, the module is realized intelligent
    generator control technology.There are used for genset automation and monitor control system of single
    unit to achieve automatic start/stop, data measurement, alarm protection.It fit with LCD display, optional
    languages interface (Chinese, English, Spanish and Russian), and it is reliable and easy to use.It’s
    achieve a precision measuring,fixed value adjustment, time setting and set value adjusting and etc.All
    parameters can be configured from front panel or through programmable USB interface via PC. It can
    be widely use in all types of automatic genset control system with compact structure, advanced circuits,
    simple connections and high reliability.


    2. Performance and characteristics
    LXC31X0 series controller has two types:
    LXC3110:ASM (Automatic Start Module),it controls generator to start/stop by remote signal;
    LXC3120:AMF (Auto Mains Failure), updates based on LXC3120, moreover, has mains electric quantity
    monitoring and mains/generator automatic transfer control function, especially for automatic system
    composed by generator and mains.
    Its main features are as follows:
     Display:132×64 LCD with emerald green backlight;
     Language:Chinese, English, Spanish and Russian;
     Operating:good feeling button pushing, long button life;
     Suitable for:3-phase 4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase 3-wire systems with
    voltage 120/240V and frequency 50/60Hz.
     Detection parameters:

     Load:
    Current IA,IB,IC
    Active Power (KW)
    Reactive Power (KVar)
    Apparent Power (KVA)
    Power Factor (PF)
    Accumulated Energy (kWh)
     Mains Monitor:With over voltage, under voltage, over frequency, under frequency, loss phase and
    reverse phase function;
     Gens Monitor:With over voltage, under voltage, over frequency, under frequency, loss phase and
    reverse phase function;
     Acquisition parameters:
    Temp. (WT) °C/ °F both be displayed


    Oil pressure (OP) kPa/Psi/Bar all be displayed
    Engine Speed (RP) RPM (Unit)
    Battery Voltage (VB) V (unit)
    Charger Voltage (VD) V (unit)
    Hours counter (HC): Max. 999999 hours
    Start times: Max.999999 times
     Protection: Automatic start/stop of the genset, ATS(Auto Transfer Switch) control with perfect fault
    indiCAT-parts-partsion and protection function;
     Output Control:With ETS, idle control, pre-heat control, speed raise control and speed drop control,
    All output ports are relay-out;
     Parameter Settings:All the parameters can be adjusted using front panel of the controller or use the
    computer through USB to connect directly to controller settings, all is not lost when power down
    parameter system;
     Sensor Detection:More kinds of curves of temperature, oil pressure, fuel level can be used directly
    and users can define the sensor curves by themselves;
     Multiple Crank Disconnect Conditions:Gens frequency,speed,oil pressure,D+;
     Widely Power supply range: DC(8~35)V, suitable to different start battery voltage environment;
     Mounting Assembly:Modular design, anti-flaming ABS plastic enclosure, plug gable connection
    terminals and embedded installation way; compact structure with easy mounting.


    3. SpecifiCAT-parts-partsion

    4. Operation
    4.1. Push buttons

    4.2. IndiCAT-parts-partsor light


    LXC3110 Panel IndiCAT-parts-partsors




    4.3. Automatic start/stop operation
    Auto mode is selected by pressing the button; a LED besides the button will illuminate to confirm the
    operation.
    4.3.1. Auto Start Sequence,
     LXC3120:When mains is abnormal (over/under voltage, loss of phase), enter into “Mains Abnormal
    Delay” and LCD displays count down time. When the delay is over, “Start Delay” timer is initiated.
     LXC3110:When “Remote Start” is active, “Start Delay” timer is initiated.
     “Start Delay” countdown will be displayed on LCD.
     When start delay is over, preheat relay energizes (if configured), “preheat delay XXs” information will
    be displayed on LCD.
     After the above delay, the Fuel Relay is energized, and then one second later, the Start Relay is
    engaged. The engine is cranked for a pre-set time. If the engine fails to fire during this cranking
    attempt then the fuel relay and start relay are disengaged for the pre-set rest period; “crank rest time”
    begins and wait for the next crank attempt.
     Should this start sequence continue beyond the set number of attempts, the start sequence will be
    terminated, the first line of LCD display will be highlighted with black and Fail to Start fault will be
    displayed.
     In case of successful crank attempt, the “Safety On” timer is activated, allowing Low Oil Pressure,
    High Temperature, Under speed, Charge Alternator Failure and Aux. inputs (configured) to stabilize
    without triggering the fault. As soon as this delay is over, “start idle” delay is initiated (if configured).
     During “start idle” delay, under speed, under frequency, under voltage alarms are inhibited. When this
    delay is over, “warming up” delay is initiated (if configured).
     After the “warming up” delay, if generator status is normal, its indiCAT-parts-partsor will be illuminated. If generator
    voltage and frequency have reached on-load requirements, then the generator close relay will be
    energized; genset will take load; generator power indiCAT-parts-partsor will illuminate and generator will enter into
    Normal Running status. if voltage or frequency is abnormal, the controller will initiate shutdown alarm
    (alarm information will be displayed on LCD).
    4.3.2. Auto Stop Sequence,
     LXC3120:During normal running process, if mains normal, enters into “Mains Normal Delay”. When
    mains indiCAT-parts-partsor illuminates, “Stop Delay” begins.
     LXC3110:When the “Remote Start” signal is removed, the stop delay is initiated.
     Once this “stop delay” has expired, the Generator Breaker will open and the “Cooling Delay” is then
    initiated. After “Transfer Delay”, the mains close relay will be energized; mains will take load;
    generator power indiCAT-parts-partsor will extinguish while mains power indiCAT-parts-partsor will illuminate.
     During “Stop Idle” Delay (if configured), idle relay is energized.
     “ETS Solenoid Hold” begins, ETS relay is energized while fuel relay is de-energized.
     "Fail to Stop Delay" begins, complete stop is detected automatically.
     Generator is placed into its standby mode after its complete stop. Otherwise, fail to stop alarm is
    initiated and the corresponding alarm information is displayed on LCD


    4.4. Manual start/stop operation
     LXC3120:Manual mode is selected by pressing the button; a LED besides the button will
    illuminate to confirm the operation.
     Press key, select “Mode Select”, then choose “Test Mode”. Under the two modes,
    press button to start the genset, it can automatically judge crank success and accelerate to high
    speed running. If high temperature, low oil pressure, over speed and abnormal voltage occur during
    genset running, controller can effectively protect genset to stop. Under Manual Mode, if mains normal,
    load breaker won’t transfer; if mains abnormal, load breaker will transfer to generator. Under Test
    Mode, after genset high speed normal running, no matter mains normal or not, load will be transferred
    to generator.
     LXC3110:Manual mode is selected by pressing the button; a LED besides the button will
    illuminate to confirm the operation; Then press button to start the generator, it can automatically
    judge crank success and accelerate to high speed running. If high temperature, low oil pressure, over
    speed and abnormal voltage occur during genset running, controller can effectively protect genset to
    stop. After genset high speed normal running, controller will send Gen Closed signal.
     Manual stop: pressing key can shut down the running genset.


    Buy LXC31X0 Series Diesel Generator Control Panel 32 Bit Arm Processor at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Guangdong ALI Testing Equipment Co,.Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 chinacsw.com. All rights reserved.